Changes between Version 335 and Version 336 of docs/CommissioningPlan
- Timestamp:
- 10/11/23 17:08:06 (13 months ago)
Legend:
- Unmodified
- Added
- Removed
- Modified
-
docs/CommissioningPlan
v335 v336 242 242 ||P3.16 ||[wiki:/docs/CommissioningPlan/P3.16 Instrumental throughput and absolute flux calibration] (for a set of filters)||2||bad||C5 + C6||[[span(style=color: green, completed for GL and SP-1 in Com-Run-1/2)]]|| 243 243 ||P3.17||[wiki:/docs/CommissioningPlan/P3.17 Orient the apodizers (for SP-1)] ||1 (not considered for calculation)||bad||C5 + C6||[[span(style=color: green, completed)]]|| 244 ||OC5||Coronagraphic imaging - GL - field stabilized||3||good / medium||C5 + C7||[[span(style=color: red , completed (TBV by EC))]]||245 ||OC6||Coronagraphic imaging - GL - pupil stabilized||3 (not considered for calculation)||good / medium||C5 + C7||[[span(style=color: green, completed in Com-Run-1)]]||244 ||OC5||Coronagraphic imaging - GL - field stabilized||3||good / medium||C5 + C7||[[span(style=color: blue, to be done)]]|| 245 ||OC6||Coronagraphic imaging - GL - pupil stabilized||3 (not considered for calculation)||good / medium||C5 + C7||[[span(style=color: green, completed)]]|| 246 246 ||OC7||Coronagraphic imaging - FQPM - pupil stabilized||3||good / medium||C5 + C7||[[span(style=color: blue, to be done)]]|| 247 247 ||OC8||Coronagraphic imaging - SP1 - pupil stabilized||3||good / medium||C5 + C7||[[span(style=color: green, completed)]]||