Changes between Version 18 and Version 19 of docs/CommissioningPlan/P3.4


Ignore:
Timestamp:
03/03/23 14:27:50 (21 months ago)
Author:
dvassall
Comment:

--

Legend:

Unmodified
Added
Removed
Modified
  • docs/CommissioningPlan/P3.4

    v18 v19  
    1414
    1515**Procedure**
    16 The internal deformable mirror's position (TTM_DM) is optimized to have the PSF image on the intermediate focal plane centered with the occulter. We compare the PSF image, formed on the SCICAM, with the image of the occulter obtained on the SCICAM using the calibration flat-field source.
     16The internal deformable mirror's position (TTM_DM) is optimized to have the PSF image on the intermediate focal plane centered with the occulter. We compare the PSF center, measured on the SCICAM, with the center of the occulter measured on the SCICAM using the calibration flat-field source.
    1717
    1818**Templates**
     
    2121
    2222**Success criteria**
    23 - the expected accuracy of 0.2 pixels (DV: need to check if we can reach this).
     23- delta between PSF center and occulter center < 0.2 pixels.
    2424
    2525**Notes**