== P3.10 NCPA working and performance == • **Phase** : 3 • **Status** : Draft • **Category** : Nighttime testing (functionality and operability) (C4) • **Recurrence** : once at commissioning • **Duration** : 12 hours **Description** • Evaluate the NCPA working and performance using the baseline approach, phase-diversity approach, combination of both, and measurement of NCPA using the Wollaston prison & dual-band imaging. **Prerequisites** • Atmospheric conditions: ? • Authorize SHARK-NIR on the SX side. • AO working. • Target(s) at different Zenith distances with different magnitudes? **Procedure** • Acquire star of given magnitude. Start SOUL-AO. * Check the working and performance of the NCPA baseline approach. Take images at SCICAM. * Check the phase diversity approach using Wollaston prism + DI-DBI. Take images at SCICAM. * Check the phase diversity approach (using the internal calibration source). Take images at SCICAM. * Repeat for a different star (of different magnitudes and for different elevation of the telescope) **Success criteria** • ??? **Notes** **LBTO support** • SOUL-AO support **Associated SHARK-NIR personnel** **Date performed and by whom**