  • docs/CommissioningPlan/P2.9

    v6 v7  
    3535
    3636MB: concerning RR flexures, from arcetri videocon you need to keep the loop closed while going down, so this might not be optimal for us, as it means mirrors are shifted...let's discuss again [ yeah, need discussion]
     37
     38LM: I would make explicit that the scope of this test is to measure the shift of the PSF at relevant focal planes (TECCAM and SCICAM), of the pupil image and of the optical elements (in particular coronagraphic masks) for different telescope elevations and bearing rotations. Part of these measurements takes place during NCPA measurement 2.6 (PSFs shift). 
     39I do not understand this part "Change the velocity and acceleration of the movement of the telescope in elevation if required.". As Maria pointed out, I think we should not run SOUL while changing elevation, but yes, we need to discuss.