Changes between Version 31 and Version 32 of docs/CommissioningPlan/P2.6


Ignore:
Timestamp:
11/02/22 12:07:10 (2 years ago)
Author:
mbergomi
Comment:

--

Legend:

Unmodified
Added
Removed
Modified
  • docs/CommissioningPlan/P2.6

    v31 v32  
    1212
    1313**Prerequisites**
    14 - Knowledge of Argos light source magnitude and the possibility of tuning its brightness (more info pending from LBTO, jenny?).  In alternative we can change magnitude with our ND filters.
     14- Argos light source magnitude tuning or ND filters internal to SHARK-NIR will be used to test different magnitudes.
    1515- For the SN team: know in advance how many minutes of data can be downloaded from CRED2 or the ring-buffer size. At least barycenter position should be saved, in a format compatible with statistical analyses. Confirm if 10 mins are ok.
    1616
     
    2020Test A1.
    2121- Close the SHARK-NIR internal tip-tilt loop.
    22 - Take 10mins of data at the CRED2 (at loop frame rate) and SCICAM at 500 Hz.
     22- Take 10mins (TBC) of data at the CRED2 (at loop frame rate) and SCICAM at 500 Hz.
    2323- Introduce 0.5" seeing at the ASM and close the loop at 500 hz.
    2424- Close the SHARK-NIR internal tip-tilt loop.
     
    2828
    2929Test B1.
    30 - Take 10mins of data at the CRED2 and SCICAM.
     30- Take 10mins (TBC) of data at the CRED2 and SCICAM.
    3131- Introduce 0.8" seeing at the ASM and close the loop.
    3232- Close the SHARK-NIR internal tip-tilt loop.
    33 - Take 10mins of data at the CRED2 and SCICAM.
     33- Take 10mins (TBC) of data at the CRED2 and SCICAM.
    3434
    3535Test B2.
     
    3737
    3838Test C.
    39 - Repeat the above steps of test B for the differnet selected brightness of the Argos light source (TBC which magnitudes, noting that max brightness should be mag 9th in R band)
     39- Repeat the above steps of test B for the differentt selected brightness of the Argos light source (10th (max achievable), 12th, others TBC)
    4040
    4141**Procedure for finding the field center**
     
    4646
    4747**Templates**
     48
     49**Notes**
     50From Jenny: Setting the argos light source is set by adjusting the shutter.  There is no document outlining the magnitude ranges.  The brightest setting is about 10th mag and it can be adjusted down to 17.5 in varying increments.  The wfs can tell us the approximate magnitude setting and allow us to tune.  We know approximate settings for varying typical magnitudes from previous tests.  We do expect to work on tuning the wfs Flux calibration to ensure the feed back on the wfs is accurate and we obtaining the optimal loop parameters for a given magnitude.  The Flux on the wfs is translated to a magnitude.
    4851
    4952**Success criteria**