Changes between Version 20 and Version 21 of docs/CommissioningPlan/P2.6


Ignore:
Timestamp:
04/22/22 19:29:05 (3 years ago)
Author:
kradhakrishnan
Comment:

--

Legend:

Unmodified
Added
Removed
Modified
  • docs/CommissioningPlan/P2.6

    v20 v21  
    1 == P2.6 NCPA measurements ==
     1== P2.6 SHARK-NIR system-level characterization at different telescope elevations ==
    22
    33- **Phase**             :       2 
     
    55- **Category**  :       Daytime testing (functionality and operability) (C3) + Daytime calibration (C4)
    66- **Recurrence**        :       once after instrument installation at telescope platform
    7 - **Duration**  :       8 days
     7- **Duration**  :       6 days
    88
    99**Description**
    10 - Measure the Non-Common Path Aberrations (NCPA).
     10- SHARK-NIR system-level characterization and optimization as a function of the telescope elevation. Checking the pointing offset between SHARK-NIR, LBTI, and SOUL-AO. SOUL-AO tests. Measure the Non-Common Path Aberrations (NCPA).
    1111
    1212**Prerequisites**
    1313- Use the Argos swing arm / RR mounted on the SX side. SHARK-NIR aligned to telescope.
    14 - Phase-diversity algorithm is tested and working in simulation and using real-images from the SCICAM (at Padova).
     14- Phase-diversity algorithm is tested and working in simulation and using real images from the SCICAM (at Padova).
    1515
    16 **Procedure**
     16**Procedure for pointing offset measurements and characterization**
     17- TBW
     18
     19**Procedure for SOUL-AO tests**
     20- TBW
     21
     22**Procedure for NCPA**
    1723- Go to a specific elevation of the telescope.
    1824- Close the AO loop for the on-axis light source to produce the best PSF at the pin of the pyramid of the SOUL WFS. Keep that shape steady on ASM.
     
    2228- Repeat these measurements for the decided discreet zenith angles (or elevation of the telescope) and SHARK-NIR DROT angle (fixed).
    2329
     30
    2431**Templates**
    2532- SHARKNIR_di_cal_NCPA (not released)
    2633 
    2734**Success criteria**
     35- Estimate the pointing offset and conclude if it is acceptable or not. If not acceptable, take proper actions to overcome this issue.
     36- The SOUL-AO system is working in tandem with the SHARK-NIR system.
     37- Acceptable improvement of the on-axis PSF (Argos Swing arm calibration light source) while SOUL AO is closed with known disturbances.
    2838- NCPA estimated and applied on the ALPAO-DM.
    2939- Satisfactory PSF quality with closed-loop.
     
    4151**Date performed and by whom**
    4252
    43 JFA: